DS3512 重置密码
DS3512 重置密码
telnet 192.168.128.101 账户为 shellUsr 密码为 wy3oo&w4 输入 spriMenuPwdReset 然后输入 Y
日前,发现存储有问题,用stroage manager登录后,发现无法修改配置,提示有管理密码。搜集资料,搞定。
步骤如下:
--连接控制器管理口,这里以controller A为例:
[root@ijx ~]# telnet 192.168.128.101
Trying 192.168.128.102...
Connected to 192.168.128.101.
Escape character is '^]'.
VxWorks login: shellU
VxWorks login: sr
VxWorks login: shellUsr
Password:
Login incorrect
VxWorks login: shellUsr
VxWorks login: shwll
Password:
Login incorrect
Login timed out after 60 seconds!
Connection closed by foreign host.
[root@ijx ~]#
--输入要快,因为没在规定时间输入正确密码,锁定60秒。
[root@ijx ~]# telnet 192.168.128.101
Trying 192.168.128.102...
Connected to 192.168.128.101.
Escape character is '^]'.
VxWorks login: shellUsr
Password:
Login incorrect
VxWorks login: shellUsr
Password:
->
->
-> help
help Print this list
dbgHelp Print debugger help info
edrHelp Print ED&R help info
ioHelp Print I/O utilities help info
nfsHelp Print nfs help info
netHelp Print network help info
rtpHelp Print process help info
spyHelp Print task histogrammer help info
timexHelp Print execution timer help info
h [n] Print (or set) shell history
i [task] Summary of tasks' TCBs
ti task Complete info on TCB for task
sp adr,args... Spawn a task, pri=100, opt=0x19, stk=20000
taskSpawn name,pri,opt,stk,adr,args... Spawn a task
td task Delete a task
ts task Suspend a task
tr task Resume a task
tw task Print pending task detailed info
w [task] Print pending task info
Type <CR> to continue, Q<CR> to stop:
d [adr[,nunits[,width]]] Display memory
m adr[,width] Modify memory
mRegs [reg[,task]] Modify a task's registers interactively
pc [task] Return task's program counter
iam "user"[,"passwd"] Set user name and passwd
whoami Print user name
devs List devices
ld [syms[,noAbort][,"name"]] Load stdin, or file, into memory
(syms = add symbols to table:
-1 = none, 0 = globals, 1 = all)
lkup ["substr"] List symbols in system symbol table
lkAddr address List symbol table entries near address
checkStack [task] List task stack sizes and usage
printErrno value Print the name of a status value
period secs,adr,args... Spawn task to call function periodically
repeat n,adr,args... Spawn task to call function n times (0=forever)
version Print VxWorks version info, and boot line
shConfig ["config"] Display or set shell configuration variables
strFree [address] Free strings allocated within the shell (-1=all)
Type <CR> to continue, Q<CR> to stop:
NOTE: Arguments specifying 'task' can be either task ID or name.
value = 1 = 0x1
-> spriMenuPwdReset
Are you sure that you want to reset the Storage Array Password ? (Y/N): y
Storage Array Password reset successful
value = 42 = 0x2a = '*'
->
再次用storage manager管理存储时候,会提示设置新密码。可以修改为 Wy3oo&w4
版权声明:
作者:SE_Zhang
链接:https://www.cnesa.cn/1589.html
来源:CNESA
文章版权归作者所有,未经允许请勿转载。
共有 0 条评论