vmware esxi重启后,存储丢失
1. 扫描
[root@localhost:~] esxcfg-volume -l
Scanning for VMFS-6 host activity (4096 bytes/HB, 1024 HBs).
VMFS UUID/label: 6319b7da-b762d218-2419-ac1f6bd0401e/99_1
Can mount: Yes
Can resignature: Yes
Extent name: naa.55cd2e414fc3857d:3 range: 0 - 221183 (MB)
VMFS UUID/label: 60cc0145-e6398148-ba07-ac1f6bd0401e/99
Can mount: No (some extents missing)
Can resignature: No (some extents missing)
Extent name: naa.55cd2e414fc37329:3 range: 0 - 221183 (MB)
Scanning for VMFS-6 host activity (4096 bytes/HB, 1024 HBs).
VMFS UUID/label: 5df90e52-82fee578-e4cc-ac1f6b36ab6e/Backup1
Can mount: Yes
Can resignature: No (the volume is being actively used)
Extent name: naa.600d0231000325da2907883f79b289b9:1 range: 0 - 31457023 (MB)
Scanning for VMFS-6 host activity (4096 bytes/HB, 1024 HBs).
VMFS UUID/label: 5d27e65e-59843a39-2617-0cc47a28be3e/VMWare1-USS3000
Can mount: Yes
Can resignature: No (the volume is being actively used)
Extent name: naa.600d0231000325da6d0dd1e7330b8c15:1 range: 0 - 12582655 (MB)
2. 挂载
[root@localhost:~] esxcfg-volume -r 5df90e52-82fee578-e4cc-ac1f6b36ab6e
Resignaturing volume 5df90e52-82fee578-e4cc-ac1f6b36ab6e
[root@localhost:~] esxcfg-volume -r 5d27e65e-59843a39-2617-0cc47a28be3e
Resignaturing volume 5d27e65e-59843a39-2617-0cc47a28be3e
3. 进入vc存储管理重命名存储
(将丢失存储改名,然后将新添加存储改回原名)
4. 重新注册虚拟机
版权声明:
作者:SE_Gao
链接:https://www.cnesa.cn/735.html
来源:CNESA
文章版权归作者所有,未经允许请勿转载。
THE END
0
二维码
打赏
海报
vmware esxi重启后,存储丢失
1. 扫描
[root@localhost:~] esxcfg-volume -l
Scanning for VMFS-6 host activity (4096 bytes/HB, 1024 HBs).
VMFS UUID/label: 6319b7da-b762d218-2419-ac1f6bd0401e/99_1
Can mount: Yes
Can resignature: Yes
Extent name: naa.55cd2e414fc3857d:3 range: 0 - 221183 (MB)
VMFS UUID/label: 60cc0145-e6398148-ba07-ac1f6bd0401e/99
Can mount: No (some extents missing)
Can resignature: No (some extents missing)
Extent name: naa.55cd2e414fc37329:3 range: 0 - 221183 (MB)
Scanning for VMFS-6 host activity (4096 bytes/HB, 1024 HBs).
VMFS UUID/label: 5df90e52-82fee578-e4cc-ac1f6b36ab6e/Backup1
Can mount: Yes
Can resignature: No (the volume is being actively used)
Extent name: naa.600d0231000325da2907883f79b289b9:1 range: 0 - 31457023 (MB)
Scanning for VMFS-6 host activity (4096 bytes/HB, 1024 HBs).
VMFS UUID/label: 5d27e65e-59843a39-2617-0cc47a28be3e/VMWare1-USS3000
Can mount: Yes
Can resignature: No (the volume is being actively used)
Extent name: naa.600d0231000325da6d0dd1e7330b8c15:1 range: 0 - 12582655 (MB)
2. 挂载
[root@localhost:~] esxcfg-volume -r 5df90e52-82fee578-e4cc-ac1f6b36ab6e
Resignaturing volume 5df90e52-82fee578-e4cc-ac1f6b36ab6e
[root@localhost:~] esxcfg-volume -r 5d27e65e-59843a39-2617-0cc47a28be3e
Resignaturing volume 5d27e65e-59843a39-2617-0cc47a28be3e
3. 进入vc存储管理重命名存储
(将丢失存储改名,然后将新添加存储改回原名)
4. 重新注册虚拟机
共有 0 条评论