NE40E-X3 V600R001 ospf震荡问题

问题描述

OSPF邻居震荡,设备重启之后故障仍然存在

处理过程

ospf震荡原因为ospf hello超时,即保活时间内未收到hello报文超时down

Aug 30 2023 19:06:35 AL_ZD_NE40E_X3 %OSPF/3/NBR_CHG_DOWN(l)[1]:Neighbor event:neighbor state changed to Down. (ProcessId=1, NeighborAddress=x.x.x.x, NeighborEvent=InactivityTimer, NeighborPreviousState=Full, NeighborCurrentState=Down)

Aug 30 2023 19:03:38 AL_ZD_NE40E_X3 %OSPF/3/NBR_CHG_DOWN(l)[14]:Neighbor event:neighbor state changed to Down. (ProcessId=1, NeighborAddress=x.x.x.x, NeighborEvent=InactivityTimer, NeighborPreviousState=Exchange, NeighborCurrentState=Down)

Aug 30 2023 19:02:41 AL_ZD_NE40E_X3 %OSPF/3/NBR_CHG_DOWN(l)[23]:Neighbor event:neighbor state changed to Down. (ProcessId=1, NeighborAddress=x.x.x.x, NeighborEvent=InactivityTimer, NeighborPreviousState=Full, NeighborCurrentState=Down)

Aug 30 2023 18:55:30 AL_ZD_NE40E_X3 %OSPF/3/NBR_CHG_DOWN(l)[60]:Neighbor event:neighbor state changed to Down. (ProcessId=1, NeighborAddress=x.x.x.x, NeighborEvent=InactivityTimer, NeighborPreviousState=Full, NeighborCurrentState=Down)

Aug 30 2023 18:53:45 AL_ZD_NE40E_X3 %OSPF/3/NBR_CHG_DOWN(l)[88]:Neighbor event:neighbor state changed to Down. (ProcessId=1, NeighborAddress=x.x.x.x, NeighborEvent=InactivityTimer, NeighborPreviousState=Full, NeighborCurrentState=Down)

1、查看cpu-defend,发现有大量上送cpuospf报文超cpcar丢弃

download.png

 

2、查看设备记录的攻击溯源,发现GigabitEthernet1/0/1.20端口收到大量的ospf hello组播报文

[AL_ZD_NE40E_X3-hidecmd]display attack-source-trace slot 1 original-information ...

No 2 packet Info:

Interface Name    : GigabitEthernet1/0/1.20

PeVlanid          : 20

CeVlanid          : 0

Attack Type       : Application apperceive

Attack Pack Time  : 2023-08-31 10:30:55

Attack Source Data:

01 00 5e 00 00 05 28 6e d4 20 38 2b 81 00 00 14 08 00 45 c0 00 40 f4 5c 00

00 01 59 71 66 0a bc 68 21 e0 00 00 05 02 01 00 2c 0a bc 64 03 00 00 00 08

1a 0a 00 00 00 00 00 00 00 00 00 00 ff ff ff f0 00 0a 02 01 00 00 00 28 0a

bc 68 21 00 00 00

----------------------------------

download (1).png

3、排查NE设备下联的Switch交换机,发现vlan=20的端口流量达到90%,查看该端口有大量组播报文,怀疑下挂二层网络存在环路,ospf 组播报文在二层网络形成环路

NE下挂交换机的vlan=20端口shutdown,之后业务恢复正常,ospf邻居恢复稳定

download (2).png

 

根因

(1)NE下挂的二层网络存在环路,导致大量的ospf组播报文发送给NE。GigabitEthernet1/0/1.20端口收到大量的ospf组播报文,超过设备的cpcar值导致其他端口的ospf hello报文被随机丢弃,引起ospf震荡;

(2)需要排查二层环路原因

免责声明:本案例仅供参考不提供专业意见。

版权声明:
作者:SE_You
链接:https://www.cnesa.cn/502.html
来源:CNESA
文章版权归作者所有,未经允许请勿转载。

THE END
打赏
海报
NE40E-X3 V600R001 ospf震荡问题
问题描述 OSPF邻居震荡,设备重启之后故障仍然存在 处理过程 ospf震荡原因为ospf hello超时,即保活时间内未收到hello报文超时down Aug 30 2023 19:06:……
<<上一篇
下一篇>>