S6720 V2R11C10与VRM云服务器eth-trunk对接修改掩码故障
-
问题描述
故障前:s6720 g0/0/1-g0/0/4通过eth-trunk30\eth-trunk40与VRM云服务器对接,透传vlan100、vlan102,
网关在交换机vlanif100:172.16.100.254 255.255.255.0,Vlanif102:172.16.102.253 255.255.255.0
修改掩码:
1、修改交换机vlanif100、valnif102掩码为23位,业务运行正常
2、修改VRM云服务器vlanif100掩码根交换机同步后,业务中断
3、恢复交换机s6720及VRM云服务器vlanif100、vlanif102掩码为24位后互ping不通
告警信息
无
处理过程
1、把所有加入eth-trunk接口全部down,然后up,依然不通
2、分析交换机诊断信息,无告警,配置无异常
交换机侧:
interface Vlanif100
description fuwuqi
ip address 172.16.100.254 255.255.255.0
interface Vlanif102
ip address 172.16.102.253 255.255.255.0
interface Eth-Trunk30
description cna01
port link-type trunk
port trunk allow-pass vlan 2 to 4094
load-balance src-dst-mac
interface Eth-Trunk40
description cna02
port link-type trunk
port trunk allow-pass vlan 2 to 4094
load-balance src-dst-mac
interface GigabitEthernet0/0/1
eth-trunk 30
interface GigabitEthernet0/0/2
eth-trunk 30
interface GigabitEthernet0/0/3
eth-trunk 40
interface GigabitEthernet0/0/4
eth-trunk 40
服务器侧:
3、做流量统计,入方向没有流量
4、专家远程接入查看交换机侧无异常
5、云平台工程师远程接入观察,最后发现云平台缺省vlan变成了vlan0,不透传vlan,导致云平台与交换机不通
6、再次修改掩码测试,发现云服务器只要修改vlanif掩码,云平台透传vlan就自动回到缺省值vlan0
根因
修改vlanif掩码,VRM云平台透传vlan回到缺省值vlan0,导致vlan无法透传
解决方案
手动修改VRM云平台透传vlan为vlan100、vlan102,问题解决
建议与总结
无
免责声明:本案例仅供参考不提供专业意见。
版权声明:
作者:SE_Meng
链接:https://www.cnesa.cn/442.html
来源:CNESA
文章版权归作者所有,未经允许请勿转载。