启动报ORA-00211 ORA-00202错误
C:\Users\Administrator>sqlplus / as sysdba
SQL*Plus: Release 12.1.0.1.0 Production on 星期二 10月 13 21:35:45 2015 Copyright (c) 1982, 2013, Oracle. All rights reserved. 连接到: Oracle Database 12c Enterprise Edition Release 12.1.0.1.0 - 64bit Production With the Partitioning, OLAP, Advanced Analytics and Real Application Testing opt ions SQL> select open_MODE FROM V$DATABASE; select open_MODE FROM V$DATABASE * 第 1 行出现错误: ORA-01507: ?????? SQL> alter database mount; alter database mount * 第 1 行出现错误: ORA-00211: control file does not match previous control files ORA-00202: control file: ''D:\APP\ADMINISTRATOR\FAST_RECOVERY_AREA\ORCL12C\CONTROL02.CTL''
|
控制文件版本不匹配
手动把可以正常启动的机器里的
覆盖不能正常启动的机器这个路径下
然后执行
SQL> shutdown immediate;
SQL> startup
出现ora-00214错误
注:两台机器都需要执行以下
然后执行
SQL> show parameter control;
NAME TYPE --------------------/---------------- ---------------------- VALUE ------------------------------ control_file_record_keep_time integer 7 control_files string D:\APP\ADMINISTRATOR\ORADATA\O RCL12C\CONTROL01.CTL, D:\APP\A DMINISTRATOR\FAST_RECOVERY_ARE A\ORCL12C\CONTROL02.CTL control_management_pack_access string DIAGNOSTIC+TUNING SQL> alter system set control_files='S:\ORADATA\KTMS\CONTROL01.CTL' scope=spfile; 系统已更改。 SQL> shutdown abort ORACLE 例程已经关闭。 SQL> startup ORACLE 例程已经启动。 Total System Global Area 1703624704 bytes Fixed Size 2403448 bytes Variable Size 1090519944 bytes Database Buffers 603979776 bytes Redo Buffers 6721536 bytes |
问题解决完成。
版权声明:
作者:SE_Zhang
链接:https://www.cnesa.cn/1279.html
来源:CNESA
文章版权归作者所有,未经允许请勿转载。
共有 0 条评论