启动报ORA-00211 ORA-00202错误

C:\Users\Administrator>sqlplus / as  sysdba

SQL*Plus: Release 12.1.0.1.0 Production on 星期二 10 13 21:35:45 2015

Copyright (c) 1982, 2013, Oracle.  All rights reserved.

连接到:

Oracle Database 12c Enterprise Edition Release 12.1.0.1.0 - 64bit Production

With the Partitioning, OLAP, Advanced Analytics and Real Application Testing opt

ions

SQL> select open_MODE FROM V$DATABASE;

select open_MODE FROM V$DATABASE                   *

1 行出现错误:

ORA-01507: ??????

SQL> alter database mount;

alter database mount

*

1 行出现错误:

ORA-00211: control file does not match previous control files

ORA-00202: control file:

''D:\APP\ADMINISTRATOR\FAST_RECOVERY_AREA\ORCL12C\CONTROL02.CTL''

 

控制文件版本不匹配

手动把可以正常启动的机器里的

覆盖不能正常启动的机器这个路径下

然后执行

SQL> shutdown immediate;

SQL> startup

出现ora-00214错误

注:两台机器都需要执行以下
然后执行

SQL> show parameter control;

NAME                                 TYPE

--------------------/---------------- ----------------------

VALUE

------------------------------

control_file_record_keep_time        integer

7

control_files                        string

D:\APP\ADMINISTRATOR\ORADATA\O

RCL12C\CONTROL01.CTL, D:\APP\A

DMINISTRATOR\FAST_RECOVERY_ARE

A\ORCL12C\CONTROL02.CTL

control_management_pack_access       string

DIAGNOSTIC+TUNING

SQL> alter system set control_files='S:\ORADATA\KTMS\CONTROL01.CTL'  scope=spfile;

系统已更改。

SQL> shutdown abort

ORACLE 例程已经关闭。

SQL> startup

ORACLE 例程已经启动。

Total System Global Area 1703624704 bytes

Fixed Size                  2403448 bytes

Variable Size            1090519944 bytes

Database Buffers          603979776 bytes

Redo Buffers                6721536 bytes

问题解决完成。

阅读剩余
THE END